| | |  | | |  |  | | | Fluke Ti100 Series Thermal Imagers | | |  |  | | | Ti100 | TiR110 | TiR125 | ResolutionThe higher, the better | 160 x 120 | 160 x 120 | 160 x 120 | Temp. measurement range | -20 °C to +250 °C (-4 °F to +482 °F) | -20 °C to +150 °C (-4 °F to +302 °F) | -20 °C to +150 °C (-4 °F to +302 °F) | Thermal sensitivity (NETD)The lower, the better | = 0.10 °C at 30 °C target temp (100 mK) | = 0.08 °C at 30 °C target temp (80 mK) | = 0.08 °C at 30 °C target temp (80 mK) | IR-Fusion® viewing modes | IR only | Full IR, picture-in-picture | Full IR, picture-in-picture, AutoBlend™ | Color palettes | 4 | 11 | 16 | Voice annotation | - | Yes | Yes | Level and span | Manual and auto | Manual and auto | Manual and auto | Dew point alarm | Yes | - | Yes | Optional lenses | - | - | - | Battery | Field replaceable, rechargeable (1) | Field replaceable, rechargeable (1) | Field replaceable, rechargeable (2) | Fluke P3 Series Thermal Imagers for Buildings Comparison | | |  |  | | | TiR27 | TiR29 | TiR32 | ResolutionThe higher, the better | 240 x 180 | 280 x 210 | 320 x 240 | Temp. measurement range | -4 °F to -302 °F | -4 °F to -302 °F | -4 °F to -302 °F | Thermal sensitivity (NETD)The lower, the better | = 0.045 °C (45 mK) | = 0.045 °C (45 mK) | = 0.04 °C (40 mK) | IR-Fusion® viewing modes | Full IR, picture-in-picture, blending | Full IR, picture-in-picture, blending | Full IR, picture-in-picture, blending | Emissivity correction | On-board | On-board | On-board | Voice annotation | Yes | Yes | Yes | Optional lenses | Yes | Yes | Yes | Battery | Replaceable (2) | Replaceable (2) | Replaceable (2) | Fluke Ti Series Thermal Imagers for Buildings Comparison Product Comparison This comparison table highlights the key differences between the models. Use our Product Selection Tool to view a complete spec-by-spec comparison. | | |  |  | | | TiS | TiR | TiR1 | ResolutionThe higher, the better | 120 x 120 | 160 x 120 | 160 x 120 | Temp. measurement range | -4°F to +212°F | -4°F to +212°F | -4°F to +212°F | Thermal sensitivity (NETD)The lower, the better | =0.1 °C (100mk) | =0.1 °C (100mk) | =0.07 °C (70mk) | IR-Fusion® viewing modes | IR Only | Full IR, picture-in-picture | Full IR, picture-in-picture, blending | Color palettes | 3 | 4 | 6 | Voice annotation | - | - | Yes | Level and span | Auto and lock only | Auto/manual | Auto/manual | Dew point alarm | - | - | - | Optional lenses | - | - | - | Battery | Internal | Internal | Internal | « Return to Thermal Imagers for Buildings | |
|
|
|
|
|
|
|
|
|
|
|