中国

80i-110s 交/直流电流钳

  • Fluke 80i-110s AC/DC Current Clamp

主要特性

  • Current Range: 0.1 to 100A DC or 0.1 to 100A AC
  • Basic Accuracy (DC to 1kHz):
    100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
    10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA
    40A to 80A +/- 12% of reading + 50mA
    80 to 100A +/- 15% of reading
  • Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
  • Bandwidth: 1Hz to 20kHz
  • Working Voltage: 600V AC rms
  • Maximum Conductor Size: 11.8 mm (.46 inch) diameter
  • Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

产品概述: 80i-110s 交/直流电流钳

80i-110交/直流电流钳与任何福禄克示波表、功率谐波分析仪、万用表或其他电压测量工具兼容,其具有以下特点:BNC输入连接器或如果使用仪表,使用适配器PM9081/ 001将香蕉插头转换为BNC连接器。

产品规格: 80i-110s 交/直流电流钳

Specifications
Nominal current range 10 A, AC/DC
100 A, AC/DC
Continuous current range 0.1 A - 10 A AC/DC
1 A - 100 A AC/DC
Maximum non-destructive current 140 A - 2 kHz
Lowest measurable current 0.1 A
Basic accuracy 100 mV/A setting: 50 mA to 10 A ±3% of reading +50 mA
10 mV/A setting: 50 mA to 40 A ±4% of reading +50 mA
40 A to 80 A ±12% of reading +50 mA
80 to 100 A ±15% of reading
Useable frequency DC - 100 kHz
Output level(s) 10 A range: 100 mV/A
100 A range: 10 mV/A
Zero error adjustment Yes
Safety Specifications
Safety CAT II, 600 V
CAT III, 300 V
Maximum voltage 600 V
Mechanical and General Specifications
Warranty 1 year
Battery life 9 V, 55 h
Maximum conductor diameter 11.8 mm
Output cable length 1.6 m
BNC adapter Yes

型号: 80i-110s 交/直流电流钳

Fluke 80i 110s
交/直流电流钳