Fluke t3000 FC Wireless Temperature Kit
āļāļļāļāļĨāļąāļāļĐāļāļ°āļŠāļģāļāļąāļ
The Fluke FC Wireless t3000 Temperature Kit provides measurement of many common electrical parameters, and lets you correlate these with temperature readings
The Fluke 3000 FC Series Wireless Multimeter with the Fluke ConnectÂŪ app has all the essentials for convenient test and measurement troubleshooting:
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
With the Fluke t3000 FC Wireless K-Type Temperature Module you can:
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
āļ āļēāļāļĢāļ§āļĄāļāļĨāļīāļāļ āļąāļāļāđ: Fluke t3000 FC Wireless Temperature Kit
The Fluke FC Wireless t3000 Temperature Kit is part of the Fluke Connect team of wireless test tools
Connect the t3000 FC Wireless Temperature Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.
Youâll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke ConnectÂŪ modules as a system for multiple measurements.
From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Now you can take readings on moving machinery, with only the measurement module in harmâs way.
āļāđāļāļĄāļđāļĨāļāļģāđāļāļēāļ°: Fluke t3000 FC Wireless Temperature Kit
Fluke 3000 FC Wireless Digital Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ¹([% of Reading] + [Number of least significant digits]).
AC Voltage | |||||
Range 1 | Resolution | Accuracy 2 3 4 | Accuracy 2 3 4 | ||
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||||
600.0 mV | 0.1 mV | 1.0% + 3 | 2.0% + 3 | ||
6.000 V | 0.001 V | ||||
60.00 V | 0.01 V | ||||
600.0 V | 0.1 V | ||||
1000 V | 1 V | ||||
1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of âĪ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add Âą(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | |||||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||||
Function | Range | Resolution | Accuracy | ||
mV | 600.0 mV | 0.1 mV | 0.09% + 2 | ||
V | 6.000 V | 0.001 V | 0.09% + 2 | ||
60.00 V | 0.01 V | ||||
600.0 V | 0.1 V | ||||
1000 V | 1 V | 0.15% + 2 | |||
ÎĐ | 600 ÎĐ | 1 ÎĐ | Meter beeps at < 25 ÎĐ, beeper detects opens or shorts of 250 Ξs or longer. | ||
ÎĐ | 600.0 ÎĐ | 0.1 ÎĐ | 0.5% + 2 | ||
6.000 kÎĐ | 0.001 kÎĐ | 0.5% + 1 | |||
60.00 kÎĐ | 0.01 kÎĐ | ||||
60.00 kÎĐ | 0.1 kÎĐ | ||||
600.0 kÎĐ | 0.001 MÎĐ | ||||
50.00 MÎĐ | 0.01 MÎĐ | 1.5% + 3 | |||
Diode test | 2.000 V | 0.001 V | 1% + 2 | ||
ÂĩF | 1000 nF | 1 nF | 1.2% + 2 | ||
10.00 ΞF | 0.01 ΞF | ||||
100.0 ΞF | 0.1 ΞF | ||||
9999 ΞF1 | 1 ΞF | 10% typical | |||
1. In the 9999 ΞF range for measurements to 1000 ΞF, the measurement accuracy is 1.2% + 2. | |||||
AC and DC Current | |||||
Function | Range 1 | Resolution | Accuracy | ||
mA AC (45 Hz to 1 kHz) | 60.00 mA | 0.01 mA | 1.5% + 3 | ||
400.0 mA 3 | 0.1 mA | ||||
mA DC 2 | 60.00 mA | 0.01 mA | 0.5% + 3 | ||
400.0 mA 3 | 0.1 mA | ||||
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | |||||
Frequency | |||||
Range | Resolution | Accuracy 1 | |||
99.99 Hz | 0.01 Hz | 0.1% + 1 | |||
999.9 Hz | 0.1 Hz | ||||
9.999 kHz | 0.001 kHz | ||||
99.99 kHz | 0.01 kHz | ||||
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||||
Input Characteristics | |||||
Function | Overload protection | Input impedance (nominal) | Common mode rejection ratio (1 kÎĐ unbalance) | Normal mode rejection | |
1100 Vrms | > 10 MÎĐ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
1100 Vrms | > 10 MÎĐ < 100 pF | > 60 dB, DC to 60 Hz | |||
1100 Vrms | > 10 MÎĐ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
Open circuit test voltage | Full scale voltage | Typical short circuit current | |||
To 6 MÎĐ | 50 MÎĐ | ||||
1100 V RMS | < 2.7 VDC | < 0.7 VDC | < 0.9 VDC | < 350 mA | |
1100 Vrms | < 2.7 VDC | 2.000 VDC | < 1.1 mA | ||
mA Function | |||||
Overload Protection | Fused, 44/100 A, 1000 V FAST Fuse | ||||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||||
MIN/MAX Recording Accuracy | |||||
DC functions | The specified accuracy of the measurement function Âą 12 counts for changes > 350 mS in duration. | ||||
AC functions | The specified accuracy of the measurement function Âą 40 counts for changes > 900 mS in duration. | ||||
General Specifications | |||||
Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | ||||
ÎĐ fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||||
Display (LCD) | Update rate | 4/sec | |||
Volts, amps, ohms | 6000 counts | ||||
Frequency | 10,000 counts | ||||
Capacitance | 1,000 counts | ||||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||||
Battery life | 250 hours minimum | ||||
RF communications | 2.4 GHZ ISM Band | ||||
RF communication range | Open air, unobstructed | Up to 20 m | |||
Obstructed, sheetrock wall | Up to 6.5 m | ||||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5 m | ||||
Temperature | Operating | -10°C to 50°C | |||
Storage | -40°C to 60°C | ||||
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | ||||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | ||||
Altitude | Operating | 2,000 m | |||
Storage | 12,000 m | ||||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE | ||||
Safety compliance | ANSI/ISA 61010-1 / (82.02.01) | 3rd edition | |||
CAN/CSA-C22.2 No 61010-1-12 | 3rd edition | ||||
UL 61010-1 | 3rd edition | ||||
IEC/EN 61010-1 | 2010 | ||||
Certifications | CSA, FCC, CE | ||||
Ingress Protection (IP) rating | IP54 | ||||
Pollution degree | 2 | ||||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||||
Weight | 340 g (12 oz) | ||||
Warranty | Three years | ||||
Not compatible with Fluke CNX test tools |
Fluke t3000 FC Wireless K-Type Temperature Module
General Specifications | ||||
Range K-Type | -200°C to 1372°C | |||
Resolution | 0.1°C | |||
Accuracy | ¹[0.5% + 0.5°C] counts | |||
Input terminals | K-type mini | |||
LCD w/backlight | 3 Â― digits | |||
Log rate/interval | 1 sec minimum/adjustable by PC | |||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
Battery life | 400 hours | |||
Memory | Record up to 65,000 readings | |||
RF communications | 2.4 GHZ ISM Band | |||
RF communication range | Open air, unobstructed | Up to 20 m | ||
Obstructed, sheetrock wall | Up to 6.5 m | |||
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
Operating temperature | -10°C to +50°C | |||
Storage temperature | -40°C to +60°C | |||
Temperature coefficient | 0.01% of reading +0.03°C per °C | |||
Temperature scale | ITS-90 | |||
Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
Altitude | Operating | 2,000 m | ||
Storage | 12,000 m | |||
EMC | EN 61326-1:2006 | |||
Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
Ingress Protection (IP) rating | IP42 | |||
Pollution Degree | 2 | |||
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
Weight | .22 kg (8 oz) | |||
Warranty | Three years | |||
Not compatible with Fluke CNX test tools |
āļĢāļļāđāļ: Fluke t3000 FC Wireless Temperature Kit
80PK-1 K-Type Bead Thermocouple
Includes:
- Fluke 3000 FC Series Wireless Multimeter
- Fluke t3000 K-Type Thermocouple Thermometer
- TL175 Test Leads
- AC175 Alligator Clips
- Other K-Type temperature probes also available
- Magnetic hanging strap
āļāļđāđāļĄāļ·āļāđāļĨāļ°āđāļŦāļĨāđāļāļāđāļāļĄāļđāļĨ: Fluke t3000 FC Wireless Temperature Kit
- 287/289 | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 287/289 | āļāđāļāļĄāļđāļĨāđāļŠāļĢāļīāļĄāļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 3000 FC | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 789/787B | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 789/787B | āļāđāļāļĄāļđāļĨāđāļŠāļĢāļīāļĄāļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 3000 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- 3000 FC | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- 3000 FC | āļāđāļāļĄāļđāļĨāđāļŠāļĢāļīāļĄāļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- a3000 FC | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- a3000 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- a3001 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- a3001 FC | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- a3002 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- a3002 FC | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- Fluke Connect | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- Fluke Connect Wi-Fi to Thermal Imager | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- ir3000 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- pc 3000 FC | āļāļģāđāļāļ°āļāļģāđāļāļāļēāļĢāđāļāđāļāļēāļ
- Radio Frequency Data Class B | āļāļģāđāļāļ°āļāļģāđāļāļāļēāļĢāđāļāđāļāļēāļ
- t3000 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- t3000 FC | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- v3000 FC | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- v3000 FC v3001 FC | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- Connecting a thermal imager to your iPhone
- Connecting multiple tools at the same time with Fluke ConnectÂŪ
- Connecting the T3000 FC with the Fluke ConnectâĒ app
- How to create an equipment baseline with EquipmentLogâĒ history
- How to email a measurement using the Fluke Connect app
- How to record measurements and graphs
- How to save measurements to EquipmentLogâĒ history
- How to share measurements on equipment using the Fluke ConnectâĒ app
- Identifying intermittent conditions with TrendItâĒ graphs
- Introduction to 789FC
- Measurement history in one place using EquipmentLogâĒ history
- Measuring from a safe distance using the Fluke ConnectâĒ app
- Performing predictive maintenance with Fluke ConnectâĒ
- Saving measurements with AutoRecordâĒ measurements
- Share equipment health with EquipmentLogâĒ history
- Using ShareLiveâĒ video call to share live measurements and video
- Viewing and graphing three phase measurements